Rooftop packaged units do most of the heating and cooling in retail, restaurant, office, and light industrial buildings across Collin County. They also sit in direct Texas sun, take hail, and are usually ignored until a tenant calls. TechBridge Pacific HVAC Corp is a commercial-only contractor based in Melissa, TX. We repair, replace, and maintain rooftop units from 3 to 25 tons for building owners, property managers, and tenants in McKinney, Frisco, Plano, Allen, and the surrounding North Dallas area.
Call (469) 609-6204 or request service online. Same-day response for no-cooling and no-heat calls.
RTU Repair
We work on Carrier, Trane, Lennox, York, Daikin, Aaon, Rheem, and Goodman rooftop units, gas/electric and heat pump, single-stage through variable-speed. Common repairs:
- Compressor, contactor, capacitor, and hard-start replacement
- Condenser and evaporator fan motor, belt, pulley, and bearing replacement
- Refrigerant leak location and repair, recovery, evacuation, and weighed-in charge
- TXV and metering device replacement
- Gas heat: igniter, flame sensor, gas valve, inducer, pressure switch, and heat exchanger inspection
- Economizer actuators, dampers, sensors, and controller repair
- Thermostat, control board, and building-automation integration
- Condensate drain, pan, and overflow switch repair
How we diagnose an RTU
An RTU that is “low on Freon” every summer is an RTU with a leak, and a compressor that trips on high pressure every afternoon has a reason. On every diagnostic we measure superheat and subcooling, delta-T across the evaporator, static pressure and airflow, and compressor amp draw against nameplate. On a suspect compressor we run a megohm test to ground before recommending anything. On gas heat we check manifold pressure, temperature rise, and flame signal. You receive a written summary of what we measured and what failed, with a repair quote and, where relevant, a replacement number to compare it against.
RTU Replacement
Replacement is the right call when the unit is 15 or more years old, runs R-22, has a failed compressor or heat exchanger, or has already absorbed a couple of major repairs. It is also the right call when the unit was never sized correctly to begin with. We handle the full project:
- Load and airflow review so the new unit matches the space, not just the old nameplate
- Curb adapters for footprint changes between the old and new unit, so the roof is not opened
- Crane scheduling and rigging coordination
- Electrical, gas, and condensate connections; disconnect and breaker sizing
- Economizer, thermostat, and controls setup
- Commissioning: refrigerant charge verified by subcooling and superheat, static pressure, temperature rise, and economizer operation recorded before we leave the roof
We give you a written scope with the model, the efficiency rating, and what is and is not included. For multi-unit replacements we can phase the work so the building never loses all of its cooling at once. Typical replacement lead time depends on unit availability.
Economizers
Most RTUs over 5 tons in North Texas have an economizer, and a large share of them are broken: dampers stuck, actuators dead, or sensors disconnected. A stuck-open economizer pulls hot outdoor air across the coil all summer and can add 20 to 30 percent to cooling runtime. A stuck-closed one loses free cooling in spring and fall and can starve the space of ventilation. We test economizer operation on every PM visit and repair or replace actuators, dampers, and controllers as needed.
Rooftop Unit Preventive Maintenance
Quarterly RTU maintenance is the difference between a compressor that lasts twelve years and one that lasts seven. Each visit includes:
- Filter replacement (filters included on maintenance plans)
- Condenser coil cleaning; evaporator coil inspection and cleaning as needed
- Belt tension and condition, pulley alignment, bearing lubrication
- Refrigerant charge verified by superheat and subcooling, not just pressures
- Compressor and fan motor amp draw logged against nameplate
- Electrical: contactors, capacitors, wiring terminations, disconnect
- Condensate drain cleared and pan inspected
- Economizer damper and actuator operation
- Thermostat calibration and schedule check
- Gas heat inspection in fall: igniter, flame sensor, heat exchanger, temperature rise
Plans start at $179 per month for one to two units with priority dispatch, no diagnostic fee, 10 percent off repairs, and filters and belts included. Full details on the maintenance agreements page.
Why TechBridge Pacific
Two technicians, commercial-only, TDLR license TACLA 00151786R, EPA 608 certified, with factory training from LG and Daikin (see certifications). We do not run a residential division, which means our tooling, parts stock, and schedule are built around commercial equipment on commercial roofs. We also service commercial refrigeration and kitchen exhaust and make-up air, so a restaurant or grocery can call one number for the whole building.
Service Area
McKinney, Allen, Melissa, Anna, Prosper, Celina, Frisco, Plano, Richardson, and Dallas.
Frequently Asked Questions
How do I know if my rooftop unit should be repaired or replaced?
Under 10 to 12 years old with a single failed component: repair. Over 15 years, running R-22, or facing a compressor or heat exchanger replacement: usually replace. We give you both numbers and the reasoning, and the decision is yours.
What size rooftop units do you work on?
Packaged units from 3 to 25 tons, gas/electric and heat pump, single-zone and multi-zone. Larger equipment is handled case by case.
Do you handle the crane and the curb adapter for a replacement?
Yes. We coordinate the crane, fabricate or order the curb adapter when the footprint changes, and handle electrical, gas, and controls so the replacement is a single scope with one point of contact.
What does an RTU diagnostic cost?
Our commercial diagnostic fee and hourly labor rates are published on the pricing page. Maintenance plan customers pay no diagnostic fee.
Do you offer after-hours service?
Yes, for commercial customers, at the after-hours rates listed on our pricing page.
Can you work with our property management company or a tenant directly?
Both. We regularly work with property managers on multi-tenant buildings and with tenants who are responsible for their own HVAC under the lease. We can invoice either party and provide documentation for the other.
My RTU works but the building is never comfortable. Is that an RTU problem?
Sometimes. It can also be a broken economizer, an undersized unit, a duct problem, or, in restaurants, a kitchen exhaust system pulling the building into negative pressure. We check the whole picture before recommending equipment.
How often should a rooftop unit be serviced?
Quarterly. North Texas summers are hard on condensers, and spring cottonwood and fall leaves each need a coil cleaning. Our plans are built around four visits a year.
Rooftop Unit Down? Call Now.
Or request service online. TechBridge Pacific HVAC Corp, Melissa, TX. License TDLR TACLA 00151786R.